手機版| 您好,歡迎訪問機交網(wǎng)! 網(wǎng)站地圖| 聯(lián)系我們

Hawke非鎧接管式防爆格蘭(501/414系列)

點擊圖片查看原圖
品 牌: Hawke非鎧接管式防爆格蘭(501/414系列) 
單 價: 面議 
起 訂:  
供貨總量:
所在地: 上海
有效期至: 長期有效
最后更新: 2025-03-31 09:20
詢價
公司基本資料信息
您還沒有登錄,請登錄后查看聯(lián)系方式
 
還不是會員,立即免費注冊
 
 
產(chǎn)品詳細(xì)說明
Hawke非鎧接管式防爆格蘭(501/414系列) 

Hawke防爆格蘭代理商:上海頤品自動化科技有限公司 

關(guān)鍵詞:Hawke防爆格蘭,Hawke防爆葛蘭,Hawke防爆填料函,Hawke防爆密封接頭

Hawke非鎧防爆格蘭,Hawke鎧裝防爆格蘭,Hawke防爆變徑,Hawke防爆呼吸閥堵頭Hawke 501/414 seris Cable glands

Hawke非鎧接管式防爆格蘭(501/414系列)

Hawke代理商:上海頤品自動化科技有限公司

Hawke非鎧防爆格蘭(501/414系列)示例圖1

Hazardous Area Cable Glands from Hawke

Hawke 501/414 cable glands are suitable for use with non-armoured elastomer and plastic insulated cables installed in conduit for both outdoor and indoor use.

Hawke 501/414 cable glands are dual certified Exd and Exe and suitable for installation in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC, 3.0-65.3mm outside cable diameters.

When used in increased safety applications the Hawke cable gland can be used to terminate braided cables where the braid and the cable outer sheath enter into the electrical enclosure or junction box.

♦ Exdb IIC Gb, Exe IIC Gb, Extb IIIC, Db Non-aromoured Cables ATEX & IECEx Cable Gland.

Hawke 501/414 cable gland is suitable for cable termination and installation in Zone 1 (21), Zone 2 (22) and Division 2 hazardous areas.

  • Flameproof Exdb

  • Increased Safety Exeb

  • Dust Extb

  • Dual Certified Cable Gland For Hazardous Areas ATEX – IECEx

HAWKE 501/414 CABLE GLAND TECHNICAL SPECIFICATION

  1. Hazardous Area Cable Gland Classification – Exdb IIC Gb, Exeb IIC Gb, Extb IIIC Db

  2. Certificate No’s  – baseefa06ATEX0056X and IECEx BAS 06.0013X

  3. Cable Gland Zone Location – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC

  4. Construction and Test Standards – IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31

  5. Ingress Protection – IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X

  6. Deluge Protection – DTS01

  7. Operating Temperature Range  -60°C to +100°C

CABLE GLAND SELECtION TABLE FOR HAWKE 501/414

Hawke Size Ref. Male Entry Thread Size Female Entry Thread Size Cable Acceptance Details ‘G’ Compressed Length Hexagon Dimensions
Outer Sheath ‘B’
Metric NPT * Metric NPT # Standard Seal Alternative (S) Seal Across Flats Across Corners
Standard Option Min. Max. Min. Max.
Os M20 ‡ ½” M20 3.0 8.0 54.5 24.0 26.5
O M20 ‡ ½” M20 6.5 11.9 54.5 24.0 26.5
A M20 ¾” ½” M20 10.0 14.3 9.0 13.4 56.4 30.0 32.5
B M25 1″ ¾” M25 13.0 20.2 9.5 15.4 48.2 36.0 39.5
C M32 1¼” 1″ M32 19.0 26.5 15.5 21.2 61.6 46.0 50.5
C2 M40 1½” 1¼” M40 25.0 32.5 22.0 28.0 64.6 55.0 60.6
D M50 2″ 1½” M50 31.5 44.4/42.3 † 27.5 34.8 83.2 65.0 70.8
E M63 2½” 2″ M63 42.5 56.3/54.3 † 39.0 46.5 83.2 80.0 88.0
F M75 3″ 2½” M75 54.5 68.2/65.3 † 49.5 58.3 86.4 95.0 104.0

 

CABLE GLAND MATERIAL & FINISH

Hawke 501/414 cable glands are manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.

PREPARING CABLE & GLAND FOR INSTALLING HAWKE 501/414

Hawke非鎧防爆格蘭(501/414系列)示例圖2

CABLE PREPARATION

Pull sufficient length ‘I’ of cable through conduit/cable gland to suit equipment. Screw backnut (1) onto pre-threaded conduit/cable gland and tighten with spanner/wrench.

CABLE GLAND PREPARATION

Pass the cable through the entry (5) and seal which may have previously been fitted into the equipment.

Locate the running coupler (2) onto the entry (5) and tighten using a wrench/spanner until resistance is felt between the seal and cable, then turn the running coupler through a further half to one full turn to complete the inner seal, ensuring that entry (5) is prevented from turning and backnut (1) remains tight on the conduit. This procedure compresses the seal into contact with the cable outer sheath.

 

 Click Hawke Cable Glands to view the complete range of hazardous area glands certified according to ATEX & IECEx for Zone 1 / Zone 2.

Flameproof Exdb and Increased Safety Exeb (Dust Extb) Dual Certified glands from Hawke include – for further information review the product pages or contact us to discuss your cable gland requirements.

  • 501/421 Cable Gland Unarmoured   – outer cable sheath cable sealing

  • 501/423 Cable Gland Unarmoured – flameproof seal to inner/outer cable sheath with IP seal on the outer sheath

  • 501/453 Universal Cable Gland Wire Armoured Baided Steel Tape Armoured – indoor/outdoor hazardous areas

  • ICG 623 Barrier Gland Unarmoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas

  • ICG 653 Barrier Gland Armoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas


Hawke防爆格蘭(Hawke Cable Gland)

Hazardous Area Cable Glands-ATEX IECEX,Exe,Exd Group II

Hawke防爆格蘭代理商:上海頤品自動化科技有限公司

關(guān)鍵詞:Hawke防爆格蘭,Hawke防爆變徑,Hawke防爆堵頭,

Hawke防爆呼吸閥,Hawke防爆接線盒,Hawke防爆控制箱

Hawke防爆格蘭等產(chǎn)品規(guī)格書及相關(guān)證書-請咨詢上海頤品自動化科技有限公司

 

0條 [查看全部]  相關(guān)評論
 
更多..本企業(yè)其它產(chǎn)品

[ 供應(yīng)信息搜索 ]  [ ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關(guān)閉窗口 ]

客服熱線:0551-62672521 業(yè)務(wù)咨詢:0551-62672521 郵箱:2268263116@qq.com

媒體合作: 點擊這里給我發(fā)消息 ??在線客服: 點擊這里給我發(fā)消息

Copyright (c) 2012 機電產(chǎn)品交易網(wǎng) . 版權(quán)所有 皖I(lǐng)CP備12004440號-2