收藏本頁 | 設為主頁 | 隨便看看
1

上海頤品自動化科技有限公司

CMP/Hawke防爆格蘭,CCG/Peppers防爆格蘭,Eaton/Cooper/OCSG防爆格蘭防爆接線箱等

新聞中心
  • 暫無新聞
產(chǎn)品分類
站內搜索
 
您當前的位置:首頁 » 供應產(chǎn)品 » Hawke非鎧雙密封防爆格蘭(501/423系列)
Hawke非鎧雙密封防爆格蘭(501/423系列)
點擊圖片查看大圖
產(chǎn) 品: 瀏覽次數(shù):28Hawke非鎧雙密封防爆格蘭(501/423系列) 
品 牌: Hawke非鎧雙密封防爆格蘭(501/423系列) 
單 價: 面議 
最小起訂量:  
供貨總量:
發(fā)貨期限: 自買家付款之日起 3 天內發(fā)貨
更新日期: 2025-03-24 11:11  有效期至:長期有效
  詢價
詳細信息

Hawke非鎧雙密封防爆格蘭(501/423系列) 
Hawke
防爆格蘭代理商:上海頤品自動化科技有限公司 

關鍵詞:Hawke防爆格蘭,Hawke防爆葛蘭,Hawke防爆填料函,Hawke防爆密封接頭

Hawke非鎧防爆格蘭,Hawke鎧裝防爆格蘭,Hawke防爆變徑,Hawke防爆呼吸閥堵頭

Hawke 501/423 CABLE GLANDS

Hawke非鎧雙密封防爆格蘭(501/423系列)

Hawke代理商:上海頤品自動化科技有限公司

 

 

Hazardous Area Cable Glands from Hawke

Hawke 501/423 cable glands provide two independent seals on non-armoured elastomer and plastic insulated cables – the first of which is a flameproof seal on the inner or outer cable sheath, with an additional IP seal on the outer sheath.

Hawke 501/423 cable glands are dual certified Exd and Exe and suitable for installation in Zone 1 (21) and Zone 2 (22) hazardous areas, 3.2-91.6mm outside cable diameters.

When used in increased safety applications the Hawke cable gland can be used to terminate braided cables where the braid and the cable outer sheath enter into the electrical enclosure or junction box.

♦ Exdb IIC Gb, Exeb IIC Gb, Extb IIIC, Db Non-Aromoured Cables ATEX & IECEx Cable Gland

Hawke 501/423 cable gland is suitable for cable termination and installation in Zone 1 (21), Zone 2 (22) and Division 2 hazardous areas

  • Flameproof Exdb

  • Increased Safety Exeb

  • Dust Extb

  • Dual Certified Cable Gland For Hazardous Areas ATEX – IECEx

HAWKE 501/423 CABLE GLAND TECHNICAL SPECIFICATION

  1. Hazardous Area Cable Gland Classification – Exdb IIC Gb, Exed IIC Gb, Extb IIIC Db

  2. Certificate No’s  – baseefa06ATEX0056X and IECEx BAS 06.0013X

  3. Cable Gland Zone Location – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC

  4. Construction and Test Standards – IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31

  5. Ingress Protection – IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X

  6. Deluge Protection – DTS01

  7. Operating Temperature Range  -60°C to +100°C

CABLE GLAND SELECtION TABLE FOR HAWKE 501/423

HAWKE 501/423 CABLE GLAND SELECTION TABLE
Hawke Size Ref. Entry Thread Size Thread Length ‘H’ Cable Acceptance Details ‘G’ Compressed Length Hexagon Dimensions
Outer Sheath ‘B’
Metric NPT * Standard Seal Alternative (S) Seal Across Flats Across Corners
Standard Option Min. Max. Min. Max.
Os M20 ‡ ½” 15.0 3.2 8.0 40.0 24.0 26.5
O M20 ‡ ½” 15.0 6.5 11.9 40.0 24.0 26.5
A M20 ¾” ½” 15.0 10.0 14.3 9.0 13.5 40.4 30.0 32.5
B M25 1″ ¾” 15.0 13.0 20.2 9.5 15.4 44.3 36.0 39.5
C M32 1¼” 1″ 15.0 19.5 26.5 15.5 21.2 47.2 46.0 50.5
C2 M40 1½” 1¼” 15.0 25.0 32.5 22.0 28.0 49.5 55.0 60.6
D M50 2″ 1½” 15.0 31.5 44.4/42.3 † 27.5 34.8 72.5 65.0 70.8
E M63 2½” 2″ 15.0 42.5 56.3/54.3 † 39.0 46.5 64.8 80.0 88.0
F M75 3″ 2½” 15.0 54.5 68.2/65.3 † 49.5 58.3 68.0 95.0 104.0
G M80 3½” 20.0 67.0 73.0 68.0 106.4 115.0
H M90 3½” 20.0 67.0 77.6 68.0 115.0 130.0
J M100 4″ 20.0 75.0 91.6 68.0 127.0 142.0

All dimensions in millimetres (except * where dimensions are in inches).
Os – F size metric entry threads are 1.5mm pitch as standard. For G size Cable Glands and above, a 2mm pitch is supplied as standard (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering.
† Smaller value is applicable when selecting reduced NPT entry option.
‡ Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable outer sheath diameter is 10.9 mm.

CABLE GLAND MATERIAL & FINISH

Hawke 501/423 cable glands are manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard.

PREPARING CABLE & GLAND FOR INSTALLING HAWKE 501/423

 

Hawke 501/423 Cable & Gland Preparation

CABLE PREPARATION

Allow sufficient length of cable, II, to suit equipment. If required, fit shroud. Pass cable through cable gland as shown above. Note : If the equipment has a threaded entry, it may be advisable to screw the cable gland into the equipment to prevent twisting of the cable after Step B & C.

CABLE GLAND PREPARATION

Unless already screwed into the equipment hold the entry (3) in position with a spanner/wrench to prevent rotation and tighten the middle nut (2) using a wrench/spanner until resistance is felt between the seal and cable. Then turn the middle nut through a further half to one full turn to complete the inner seal

 

Hawke Cable Glands to view the complete range of hazardous area glands certified according to ATEX & IECEx for Zone 1 / Zone 2.

Flameproof Exdb and Increased Safety Exeb (Dust Extb) Dual Certified glands from Hawke include – for further information review the product pages or contact us to discuss your cable gland requirements.

  • 501/421 Cable Gland Unarmoured   – outer cable sheath cable sealing

  • 501/423 Cable Gland Unarmoured – flameproof seal to inner/outer cable sheath with IP seal on the outer sheath

  • 501/453 Universal Cable Gland Wire Armoured Baided Steel Tape Armoured – indoor/outdoor hazardous areas

  • ICG 623 Barrier Gland Unarmoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas

  • ICG 653 Barrier Gland Armoured – Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC hazardous areas

Hawke防爆格蘭(Hawke Cable Gland)

Hazardous Area Cable Glands-ATEX IECEX,Exe,Exd Group II

Hawke防爆格蘭代理商:上海頤品自動化科技有限公司

關鍵詞:Hawke防爆格蘭,Hawke防爆變徑,Hawke防爆堵頭,Hawke防爆呼吸閥,Hawke防爆接線盒,Hawke防爆控制箱

Hawke防爆格蘭等產(chǎn)品規(guī)格書及相關證書-請咨詢上海頤品自動化科技有限公司

 

  
詢價單
網(wǎng)站首頁  | 公司介紹  | 供應產(chǎn)品  | 新聞中心  | 聯(lián)系方式  | 管理入口
©2025 上海頤品自動化科技有限公司 版權所有   技術支持:機交網(wǎng)     訪問量:1555